M

Mr. Dubey • 52.26K Points
Coach

Q. If d is the distance between the flange angles,

(A) vertical stiffeners are provided in steel plate girders if the web is less than d/85
(B) vertical stiffeners are provided in high tensile steel plate girders if the web is less than d/175
(C) horizontal stiffeners are provided in steel plate girders if the web is less than d/200
(D) all the above
Correct : Option (D)

Share

Discusssion

Login to discuss.

Be the first to start discuss.